51-A17, 51-A22, 51-AT22, B51-AT22, B51-... #01AFDE

51-A17, 51-A22, 51-AT22, B51-AT22, B51-... #01AFDE

Loading Schematic

Model Numbers: 51-A17, 51-A22, 51-AT22, B51-AT22, B51-AT22-80V

Repair Parts for the Coleman Sanborn models 51-A17, 51-A22, 51-AT22, B51-AT22, B51-AT22-80V Stationary Two-Stage Electric Air Compressors

This unit originally used the B5000 pump, which is obsolete. Suggested replacement pump is the B5900
If replacing your original pump with the B5900 pump, you will need to make modifications such as:

- New Mounting Bolt Pattern 
- Smaller (A-style) vee-belt
- Flexible Transfer Tube (1 1/4" OD) with related hardware.

Specifications

B5000 Pump specs:

  • Used on the BL51AT22 and others.
  • Some parts are still available even though the whole pump is not
  • This pump is easily identified by the intercooler tube location and finned supply line.
  • Has a 17" flywheel.
  • Footprint was 9" side to side and 7.5" front to back
  • Use 3450 RPM motor.
  • Oil capacity 52 oz.

Manuals

Click here to order and download the Owner's Manual

Extras

We have Coleman Sanborn 51-A17, 51-A22 parts here. Whether you need a pressure switch or a new pump, we have your parts. Coleman Sanborn 51-A17, 51-A22 parts are easy to come by at Master Tool Repair. We have helpful sales team members that can assist you with your repair. We have accessories as well as compressor oil to keep your pump running like a top. We keep the most popular Coleman 51-A17, 51-A22 parts in stock and we can order most other parts in a matter of a few days. To make ordering easier, we have created the ability for you to order parts by simply enlarging the schematic and then using your mouse to hover over the actual part. You will see the part pop up and are able to order by simply choosing the quantity of parts that you need and adding them to your cart. Make sure to keep spare parts on hand so that your down time will be minimal. Replace your Air Filter and Oil every 3 to 4 months if used frequently. Use straight 30W compressor oil (20W below 34 deg). Drain your tank regularly to prevent rust, especially in humid climates.